Vena® Air / Air Plus
- Temperature
- −55 °C … +125 °C
- Material
- Neoprene and fiberglass.
Solutions
All products →SUBSECTORS
NEW PRODUCT
Vena® Air Craft HT / HT Plus
Flexible ducting for high-temperature air, exhaust and cooling applicati…
SUBSECTORS
NEW PRODUCT
Vena®Thermic Flow
High-Flow Reinforced EPDM Hose
APPLICATIONS
Material research
At Venair, we are in constant change, in an aim to adapt to the market advances and world’s evolution, to reach progress.
APPLICATIONS
Custom production
From one piece project to serial production, we manufacture complete custom fluid transfer systems design exclusively for your specific applications.
APPLICATIONS
Design support
From one piece project to serial production, we manufacture complete custom fluid transfer systems design exclusively for your specific application.
All products › Flexible ducting for hot air and fumes
5 references −55 to +260 °C EN 45545-2 · UL 94
Ducting moves air and gases, not liquids, so it is built light and flexible: a fabric or fibre wall, a helix to keep it round and a coating chosen for the temperature. Choose the coating by the air it will carry.
Venair’s 5 ducting hoses cover silicone-coated fibreglass for high-temperature air, exhaust and cooling up to +260 °C (Vena® Air HT, Air Craft HT), neoprene for medium temperatures (Vena® Air), neoprene classified to EN 45545-2 and UL 94 V0 for trains (Vena® Air Railway) and polyurethane ducting for sucking up abrasive particles (Vena® Pur).
5 references
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25 | 1 | 1.56 | 0.06 | 1.8 | 26 | 5.2 | 76 | 0.5 | 8 | 34.47 | 1.36 |
| 38 | 1 1/2 | 1.56 | 0.06 | 1.6 | 23 | 4.7 | 68 | 0.5 | 7 | 51.84 | 2.04 |
| 51 | 2 1/64 | 1.56 | 0.06 | 1.4 | 21 | 4.2 | 61 | 0.4 | 6 | 69.21 | 2.72 |
| 63 | 2 31/64 | 1.9 | 0.08 | 1.3 | 19 | 3.8 | 55 | 0.3 | 5 | 85.24 | 3.36 |
| 76 | 3 | 1.9 | 0.08 | 1.2 | 17 | 3.4 | 50 | 0.3 | 5 | 102.61 | 4.04 |
| 102 | 4 1/64 | 2.2 | 0.09 | 0.9 | 13 | 2.7 | 40 | 0.2 | 3 | 137.34 | 5.41 |
| 127 | 5 | 2.2 | 0.09 | 0.8 | 11 | 2.2 | 32 | 0.2 | 3 | 170.74 | 6.72 |
| 152 | 6 | 2.2 | 0.09 | 0.6 | 9 | 1.8 | 26 | 0.1 | 2 | 204.68 | 8.06 |
| 203 | 8 | 2.4 | 0.09 | 0.4 | 6 | 1.1 | 17 | 0.1 | 1 | 272.28 | 10.72 |
| 254 | 10 | 2.4 | 0.09 | 0.3 | 4 | 0.7 | 11 | 0.1 | 1 | 340.41 | 13.4 |
| 300 | 11 13/16 | 2.4 | 0.09 | 0.2 | 3 | 0.5 | 7 | 0.1 | 1 | 401.87 | 15.82 |
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25 | 1 | 2.16 | 0.09 | 2.3 | 33 | 6.8 | 99 | 0.6 | 9 | 38 | 1.49 |
| 38 | 1 1/2 | 2.16 | 0.09 | 2 | 29 | 6 | 87 | 0.5 | 8 | 57 | 2.26 |
| 51 | 2 1/64 | 2.16 | 0.09 | 1.7 | 26 | 5.3 | 77 | 0.5 | 7 | 77 | 3.03 |
| 63 | 2 31/64 | 2.5 | 0.1 | 1.5 | 23 | 4.7 | 69 | 0.4 | 6 | 95 | 3.74 |
| 76 | 3 | 2.5 | 0.1 | 1.4 | 20 | 4.2 | 61 | 0.4 | 6 | 115 | 4.51 |
| 102 | 4 1/64 | 2.8 | 0.11 | 1.1 | 16 | 3.3 | 48 | 0.3 | 4 | 154 | 6.06 |
| 127 | 5 | 2.8 | 0.11 | 0.8 | 13 | 2.6 | 38 | 0.2 | 3 | 192 | 7.54 |
| 152 | 6 | 2.8 | 0.11 | 0.6 | 10 | 2 | 30 | 0.1 | 2 | 230 | 9.05 |
| 203 | 8 | 3 | 0.12 | 0.4 | 6 | 1.3 | 19 | 0.1 | 1 | 306 | 12.05 |
| 254 | 10 | 3 | 0.12 | 0.2 | 4 | 0.8 | 12 | 0.1 | 1 | 383 | 15.08 |
From the Venair High Performance 2027 catalogue, page 31. Vena® Air / Air Plus →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25 | 1 | 1.56 | 0.06 | 1.8 | 26 | 5.2 | 76 | 0.5 | 8 | 34.47 | 1.36 |
| 38 | 1 1/2 | 1.56 | 0.06 | 1.6 | 23 | 4.7 | 68 | 0.5 | 7 | 51.84 | 2.04 |
| 51 | 2 1/64 | 1.56 | 0.06 | 1.4 | 21 | 4.2 | 61 | 0.4 | 6 | 69.21 | 2.72 |
| 63 | 2 31/64 | 1.9 | 0.08 | 1.3 | 19 | 3.8 | 55 | 0.3 | 5 | 85.24 | 3.36 |
| 76 | 3 | 1.9 | 0.08 | 1.2 | 17 | 3.4 | 50 | 0.3 | 5 | 102.61 | 4.04 |
| 102 | 4 1/64 | 2.2 | 0.09 | 0.9 | 13 | 2.7 | 40 | 0.2 | 3 | 137.34 | 5.41 |
| 127 | 5 | 2.2 | 0.09 | 0.8 | 11 | 2.2 | 32 | 0.2 | 3 | 170.74 | 6.72 |
| 152 | 6 | 2.2 | 0.09 | 0.6 | 9 | 1.8 | 26 | 0.1 | 2 | 204.68 | 8.06 |
| 203 | 8 | 2.4 | 0.09 | 0.4 | 6 | 1.1 | 17 | 0.1 | 1 | 272.28 | 10.72 |
| 254 | 10 | 2.4 | 0.09 | 0.3 | 4 | 0.7 | 11 | 0.1 | 1 | 340.41 | 13.4 |
| 300 | 11 13/16 | 2.4 | 0.09 | 0.2 | 3 | 0.5 | 7 | 0.1 | 1 | 401.87 | 15.82 |
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25 | 1 | 2.16 | 0.09 | 2.3 | 33 | 6.8 | 99 | 0.6 | 9 | 38 | 1.49 |
| 38 | 1 1/2 | 2.16 | 0.09 | 2 | 29 | 6 | 87 | 0.5 | 8 | 57 | 2.26 |
| 51 | 2 1/64 | 2.16 | 0.09 | 1.7 | 26 | 5.3 | 77 | 0.5 | 7 | 77 | 3.03 |
| 63 | 2 31/64 | 2.5 | 0.1 | 1.5 | 23 | 4.7 | 69 | 0.4 | 6 | 95 | 3.74 |
| 76 | 3 | 2.5 | 0.1 | 1.4 | 20 | 4.2 | 61 | 0.4 | 6 | 115 | 4.51 |
| 102 | 4 1/64 | 2.8 | 0.11 | 1.1 | 16 | 3.3 | 48 | 0.3 | 4 | 154 | 6.06 |
| 127 | 5 | 2.8 | 0.11 | 0.8 | 13 | 2.6 | 38 | 0.2 | 3 | 192 | 7.54 |
| 152 | 6 | 2.8 | 0.11 | 0.6 | 10 | 2 | 30 | 0.1 | 2 | 230 | 9.05 |
| 203 | 8 | 3 | 0.12 | 0.4 | 6 | 1.3 | 19 | 0.1 | 1 | 306 | 12.05 |
| 254 | 10 | 3 | 0.12 | 0.2 | 4 | 0.8 | 12 | 0.1 | 1 | 383 | 15.08 |
From the Venair High Performance 2027 catalogue, page 31. Vena® Air HT / Air HT Plus →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 25 | 1 | 2.36 | 0.09 | 2.27 | 32.92 | 6.81 | 98.75 | 0.66 | 9.57 | 38 | 1.5 |
| 50 | 1 31/32 | 2.36 | 0.09 | 1.8 | 26.1 | 5.4 | 78.3 | 0.52 | 7.54 | 75 | 2.95 |
| 75 | 2 61/64 | 2.7 | 0.11 | 1.42 | 20.59 | 4.26 | 61.77 | 0.4 | 5.8 | 113 | 4.45 |
| 100 | 3 15/16 | 3 | 0.12 | 1.13 | 16.39 | 3.39 | 49.16 | 0.31 | 4.5 | 151 | 5.94 |
| 130 | 5 1/8 | 3 | 0.12 | 0.85 | 12.33 | 2.55 | 36.98 | 0.23 | 3.34 | 196 | 7.72 |
| 200 | 7 7/8 | 3.2 | 0.13 | 0.45 | 6.53 | 1.35 | 19.58 | 0.12 | 1.74 | 302 | 11.89 |
| 300 | 11 13/16 | 3.2 | 0.13 | 0.18 | 2.61 | 0.54 | 7.83 | 0.04 | 0.58 | 452 | 17.8 |
From the Venair High Performance 2027 catalogue, page 34. Vena® Air Railway →
| ID (mm) | ID (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Vacuum (bar) | Vacuum (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|
| 50 | 1.97 | 0.56 | 8.12 | 1.68 | 24.36 | 0.22 | 3.19 | 60 | 2.36 |
| 55 | 2.17 | 0.49 | 7.11 | 1.47 | 21.32 | 0.2 | 2.9 | 65 | 2.56 |
| 60 | 2.36 | 0.43 | 6.24 | 1.29 | 18.71 | 0.18 | 2.61 | 70 | 2.76 |
| 65 | 2.56 | 0.38 | 5.51 | 1.14 | 16.53 | 0.16 | 2.32 | 75 | 2.95 |
| 70 | 2.76 | 0.34 | 4.93 | 1.02 | 14.79 | 0.15 | 2.18 | 80 | 3.15 |
| 75 | 2.95 | 0.31 | 4.5 | 0.93 | 13.49 | 0.14 | 2.03 | 85 | 3.35 |
| 80 | 3.15 | 0.28 | 4.06 | 0.84 | 12.18 | 0.12 | 1.74 | 90 | 3.54 |
| 85 | 3.35 | 0.25 | 3.63 | 0.75 | 10.88 | 0.12 | 1.74 | 95 | 3.74 |
| 90 | 3.54 | 0.23 | 3.34 | 0.69 | 10.01 | 0.11 | 1.6 | 100 | 3.94 |
| 100 | 3.94 | 0.2 | 2.9 | 0.6 | 8.7 | 0.09 | 1.31 | 110 | 4.33 |
| 105 | 4.13 | 0.19 | 2.76 | 0.57 | 8.27 | 0.09 | 1.31 | 115 | 4.53 |
| 110 | 4.33 | 0.17 | 2.47 | 0.51 | 7.4 | 0.08 | 1.16 | 120 | 4.72 |
| 115 | 4.53 | 0.16 | 2.32 | 0.48 | 6.96 | 0.08 | 1.16 | 125 | 4.92 |
| 120 | 4.72 | 0.15 | 2.18 | 0.45 | 6.53 | 0.08 | 1.16 | 130 | 5.12 |
| 125 | 4.92 | 0.14 | 2.03 | 0.42 | 6.09 | 0.07 | 1.02 | 135 | 5.31 |
| 130 | 5.12 | 0.14 | 2.03 | 0.42 | 6.09 | 0.07 | 1.02 | 140 | 5.51 |
| 135 | 5.31 | 0.13 | 1.89 | 0.39 | 5.66 | 0.06 | 0.87 | 145 | 5.71 |
| 140 | 5.51 | 0.12 | 1.74 | 0.36 | 5.22 | 0.06 | 0.87 | 150 | 5.91 |
| 150 | 5.91 | 0.11 | 1.6 | 0.33 | 4.79 | 0.06 | 0.87 | 160 | 6.3 |
| 160 | 6.3 | 0.1 | 1.45 | 0.3 | 4.35 | 0.05 | 0.73 | 170 | 6.69 |
| 170 | 6.69 | 0.09 | 1.31 | 0.27 | 3.92 | 0.05 | 0.73 | 180 | 7.09 |
| 180 | 7.09 | 0.08 | 1.16 | 0.24 | 3.48 | 0.05 | 0.73 | 190 | 7.48 |
| 200 | 7.87 | 0.07 | 1.02 | 0.21 | 3.05 | 0.04 | 0.58 | 210 | 8.27 |
| 205 | 8.07 | 0.07 | 1.02 | 0.21 | 3.05 | 0.04 | 0.58 | 215 | 8.46 |
| 220 | 8.66 | 0.06 | 0.87 | 0.18 | 2.61 | 0.04 | 0.58 | 230 | 9.06 |
| 250 | 9.84 | 0.05 | 0.73 | 0.15 | 2.18 | 0.03 | 0.44 | 260 | 10.24 |
| 255 | 10.04 | 0.05 | 0.73 | 0.15 | 2.18 | 0.03 | 0.44 | 265 | 10.43 |
| 300 | 11.81 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 310 | 12.2 |
| 305 | 12.01 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 315 | 12.4 |
| 310 | 12.2 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 320 | 12.6 |
| 315 | 12.4 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 325 | 12.8 |
| 320 | 12.6 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 330 | 12.99 |
| 325 | 12.8 | 0.04 | 0.58 | 0.12 | 1.74 | 0.02 | 0.29 | 335 | 13.19 |
| 330 | 12.99 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 340 | 13.39 |
| 335 | 13.19 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 345 | 13.58 |
| 340 | 13.39 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 350 | 13.78 |
| 345 | 13.58 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 355 | 13.98 |
| 350 | 13.78 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 360 | 14.17 |
| 400 | 15.75 | 0.03 | 0.44 | 0.09 | 1.31 | 0.02 | 0.29 | 410 | 16.14 |
| 450 | 17.72 | 0.02 | 0.29 | 0.06 | 0.87 | 0.01 | 0.15 | 460 | 18.11 |
From the Venair Life Science 2027 catalogue, page 65. Vena® Pur →
Need another size or a set length? We make hoses to order.
Request a quoteSet the angle, the bend radius and the two legs, and get the length of hose you need — with the part drawn to your figures.
Frequently asked questions
Ducting carries air or gases at low pressure, so it is lighter and more flexible; a hose carries liquids or pressurised gas and needs a stronger, reinforced wall.
Silicone-coated fibreglass: Vena® Air HT and Air Craft HT work from −55 °C to +260 °C, for hot air, exhaust extraction and thermal management.
Fire-rated ducting: Vena® Air Railway is classified HL3 R22 and R23 to EN 45545-2 and V0 to UL 94.
Polyurethane, which resists abrasion far better than rubber or PVC: Vena® Pur. See all polyurethane hoses.
Tell us about your need and we will create the optimal solution for your company.