Adaptsil
- Temperature
- Temperature on request
- Material
- Silicone
Solutions
All products →SUBSECTORS
NEW PRODUCT
Vena® Air Craft HT / HT Plus
Flexible ducting for high-temperature air, exhaust and cooling applicati…
SUBSECTORS
NEW PRODUCT
Vena®Thermic Flow
High-Flow Reinforced EPDM Hose
APPLICATIONS
Material research
At Venair, we are in constant change, in an aim to adapt to the market advances and world’s evolution, to reach progress.
APPLICATIONS
Custom production
From one piece project to serial production, we manufacture complete custom fluid transfer systems design exclusively for your specific applications.
APPLICATIONS
Design support
From one piece project to serial production, we manufacture complete custom fluid transfer systems design exclusively for your specific application.
All products › Sanitary and pharmaceutical hoses
19 references −60 to +200 °C USP Class VI · FDA · 3-A
A pharmaceutical hose is part of the process: what it releases into the product, how it survives cleaning and sterilisation and whether it can be traced matter as much as pressure and temperature. That is why the bore material and its certificates come first.
Venair’s 19 sanitary hoses are built around platinum-cured silicone tested to USP Class VI (Vena® Pharma, Pharma Clear, Pharma HP, Sil 640, Sil 650V Lastic, VENABIO® Technosil Plus), with an antimicrobial version (Vena® Aseptisil) and a silicone hose with an FKM inner layer for aggressive fluids (Vena® Pharma Seal). For solvents and harsh chemicals there are PFA-lined hoses (Venaflon®); for visible flow, translucent FEP (Vena® View); for steam, Vena® Steamflow; for powders, silicone compensators and sleeves (Vena® Pharmaloader, Sleeve).
For biopharma processes that change with every batch, see single-use tubing.
19 references
| ID (mm) | ID (in) | OD (mm) | OD (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|
| 13.1 | 0.52 | 23 | 0.91 | 114 | 1653 | 457 | 6628 | 37 | 1.46 |
| 16.3 | 0.64 | 27 | 1.06 | 102 | 1479 | 409 | 5932 | 50 | 1.97 |
| 19.6 | 0.77 | 31 | 1.22 | 87 | 1262 | 347 | 5033 | 77 | 3.03 |
| 25.5 | 1 | 38.7 | 1.52 | 65 | 943 | 260 | 3771 | 80 | 3.15 |
| 32.4 | 1.28 | 46 | 1.81 | 63 | 914 | 251 | 3640 | 100 | 3.94 |
| 39 | 1.54 | 52 | 2.05 | 55 | 798 | 220 | 3191 | 145 | 5.71 |
| 50.5 | 1.99 | 67 | 2.64 | 47 | 685 | 189 | 2741 | 210 | 8.27 |
From the Venair Life Science 2027 catalogue, page 62. Vena® Flexpure →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Bend radius (mm) | Bend radius (ft) |
|---|---|---|---|---|---|---|---|---|---|
| 10 | 25/64 | 5.7 | 0.22 | 9.86 | 143 | 29.58 | 429.02 | 16.03 | 0.05 |
| 13 | 1/2 | 5.7 | 0.22 | 8.4 | 121.83 | 25.2 | 365.49 | 25.04 | 0.08 |
| 19 | 3/4 | 5.7 | 0.22 | 6.66 | 95.72 | 19.99 | 289.93 | 43.07 | 0.15 |
| 25 | 1 | 5.7 | 0.22 | 5.63 | 81.65 | 16.9 | 245.11 | 61.1 | 0.21 |
| 32 | 1 1/4 | 5.7 | 0.22 | 4.84 | 70.19 | 14.53 | 210.73 | 82.13 | 0.27 |
| 55 | 2 11/64 | 5.7 | 0.22 | 3.47 | 50.32 | 10.41 | 150.98 | 151.24 | 0.5 |
| 63 | 2 1/2 | 5.7 | 0.22 | 3.2 | 46.41 | 9.6 | 139.23 | 175.27 | 0.58 |
| 76 | 3 | 5.7 | 0.22 | 2.85 | 41.33 | 8.56 | 124.15 | 214.33 | 0.71 |
| 102 | 4 | 5.7 | 0.22 | 2.38 | 34.51 | 7.15 | 103.7 | 292.45 | 0.96 |
From the Venair Life Science 2027 catalogue, page 60. Vena® Pharma Clear →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|
| 10 | 3/8 | 6.5 | 0.26 | 21.3 | 308.9 | 63.9 | 926.8 | 123.8 | 4.9 |
| 13 | 1/2 | 6.5 | 0.26 | 19.4 | 281.4 | 58.2 | 844.1 | 135.3 | 5.3 |
| 16 | 5/8 | 6.5 | 0.26 | 17.1 | 247.5 | 51.2 | 742.6 | 148.2 | 5.8 |
| 19 | 3/4 | 6.5 | 0.26 | 15.3 | 221.4 | 45.8 | 664.3 | 162.4 | 6.4 |
| 25 | 1 | 6.5 | 0.26 | 11.4 | 165.3 | 34.2 | 496 | 194.7 | 7.7 |
| 32 | 1 1/4 | 6.5 | 0.26 | 9.9 | 143.1 | 29.6 | 429.3 | 239.1 | 9.4 |
| 38 | 1 1/2 | 6.5 | 0.26 | 9.6 | 139.7 | 28.9 | 419.2 | 283 | 11.1 |
| 50 | 2 | 6.5 | 0.26 | 8.6 | 124.7 | 25.8 | 374.2 | 396 | 15.6 |
From the Venair Life Science 2027 catalogue, page 67. Vena® Steamflow →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Burst pressure (bar) | Burst pressure (psi) | Bend radius (mm) | Bend radius (in) | Vacuum (bar) | Vacuum (psi) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 6.35 | 1/4 | 4.83 | 0.19 | 23.74 | 344.32 | 71.22 | 1032.97 | 34 | 1.36 | 1 | 14.5 |
| 7.9 | 5/16 | 5.05 | 0.2 | 22.85 | 331.37 | 68.54 | 994.1 | 37 | 1.48 | 1 | 14.5 |
| 9.52 | 3/8 | 5.24 | 0.21 | 22.31 | 323.54 | 66.92 | 970.61 | 46 | 1.84 | 0.95 | 13.78 |
| 12.7 | 1/2 | 5.15 | 0.2 | 19.44 | 281.91 | 58.31 | 845.73 | 51 | 2.04 | 0.95 | 13.78 |
| 15.8 | 5/8 | 5.6 | 0.22 | 16.97 | 246.18 | 50.92 | 738.54 | 65 | 2.6 | 0.9 | 13.05 |
| 19.05 | 3/4 | 5.73 | 0.23 | 15.58 | 226.02 | 46.75 | 678.06 | 76 | 3.04 | 0.8 | 11.6 |
| 22 | 7/8 | 5.5 | 0.22 | 13.95 | 202.33 | 41.85 | 606.99 | 99 | 3.96 | 0.5 | 7.25 |
| 25.4 | 1 | 5.8 | 0.23 | 12.5 | 181.25 | 37.49 | 543.75 | 118 | 4.72 | 0.4 | 5.8 |
| 28 | 1 7/64 | 5 | 0.2 | 11.67 | 169.21 | 35 | 507.64 | 160 | 6.4 | 0.15 | 2.18 |
| 31.75 | 1 1/4 | 7.13 | 0.28 | 10.07 | 146.01 | 30.2 | 438.02 | 181 | 7.24 | 0.15 | 2.18 |
From the Venair Life Science 2027 catalogue, page 66. VENABIO® Technosil Plus →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Vacuum (bar) | Weight (kg/m) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|
| 13 | 1/2 | 6 | 0.24 | 10 | 145.04 | -0.9 | 0.51 | 135 | 5.31 |
| 19 | 3/4 | 6 | 0.24 | 10 | 145.04 | -0.9 | 0.67 | 188 | 7.4 |
| 25 | 1 | 6 | 0.24 | 10 | 145.04 | -0.9 | 0.88 | 225 | 8.85 |
| 32 | 1 1/4 | 6.5 | 0.26 | 10 | 145.04 | -0.9 | 1.16 | 262 | 10.31 |
| 38 | 1 1/2 | 6.5 | 0.26 | 10 | 145.04 | -0.9 | 1.43 | 338 | 13.3 |
| 51 | 2 | 7.25 | 0.28 | 10 | 145.04 | -0.9 | 1.95 | 412 | 16.22 |
| 63.5 | 2 1/2 | 8 | 0.31 | 10 | 145.04 | -0.9 | 2.75 | 450 | 17.71 |
| 76 | 3 | 8 | 0.31 | 10 | 145.04 | -0.9 | 3.2 | 525 | 20.66 |
From the Venair Life Science 2027 catalogue, page 64. Venaflon® Full-X →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|
| 10 | 3/8 | 6 | 0.24 | 10 | 145.04 | 40 | 1.58 |
| 13 | 1/2 | 6 | 0.24 | 10 | 145.04 | 45 | 1.77 |
| 16 | 5/8 | 6 | 0.24 | 10 | 145.04 | 55 | 2.17 |
| 19 | 3/4 | 6 | 0.24 | 10 | 145.04 | 65 | 2.56 |
| 25 | 1 | 6 | 0.24 | 10 | 145.04 | 85 | 3.35 |
| 32 | 1 1/4 | 6 | 0.24 | 10 | 145.04 | 120 | 4.72 |
| 38 | 1 1/2 | 6.5 | 0.26 | 10 | 145.04 | 140 | 5.51 |
| 51 | 2 | 8 | 0.31 | 10 | 145.04 | 180 | 7.09 |
| 63.5 | 2 1/2 | 8 | 0.31 | 5 | 72.52 | 320 | 12.6 |
| 76 | 3 | 8 | 0.31 | 5 | 72.52 | 380 | 14.96 |
| 100 | 4 | 9 | 0.35 | 3 | 43.51 | 500 | 19.69 |
From the Venair Life Science 2027 catalogue, page 62. Venaflon® HF →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|
| 6 | 0.24 | 6 | 0.24 | 10 | 145.04 | 40 | 1.57 |
| 13 | 1/2 | 6 | 0.24 | 10 | 145.04 | 120 | 4.72 |
| 19 | 3/4 | 6 | 0.24 | 10 | 145.04 | 120 | 4.72 |
| 25 | 1 | 6 | 0.24 | 10 | 145.04 | 150 | 5.91 |
| 32 | 1 1/4 | 6 | 0.24 | 10 | 145.04 | 200 | 7.87 |
| 38 | 1 1/2 | 7 | 0.28 | 10 | 145.04 | 250 | 9.84 |
| 51 | 2 | 8 | 0.31 | 10 | 145.04 | 300 | 11.81 |
| 63.5 | 2 1/2 | 8 | 0.31 | 5 | 72.52 | 380 | 14.96 |
| 76 | 3 | 8 | 0.31 | 5 | 72.52 | 460 | 18.11 |
From the Venair Life Science 2027 catalogue, page 63. Venaflon® HF-X →
| ID (mm) | ID (in) | Wall (mm) | Wall (in) | Working pressure (bar) | Working pressure (psi) | Vacuum (bar) | Vacuum (psi) | Weight (kg/m) | Bend radius (mm) | Bend radius (in) |
|---|---|---|---|---|---|---|---|---|---|---|
| 13 | 1/2 | 6 | 0.24 | 10 | 145.04 | -0.9 | -13.05 | 0.55 | 45 | 1.77 |
| 19 | 3/4 | 6 | 0.24 | 10 | 145.04 | -0.9 | -13.05 | 0.72 | 65 | 2.55 |
| 25 | 1 | 6 | 0.24 | 10 | 145.04 | -0.9 | -13.05 | 0.89 | 85 | 3.34 |
| 32 | 1 1/4 | 6.5 | 0.26 | 10 | 145.05 | -0.9 | -13.05 | 1.16 | 120 | 4.72 |
From the Venair Life Science 2027 catalogue, page 63. Venaflon® HR →
Need another size or a set length? We make hoses to order.
Request a quoteSaturated and superheated steam by pressure or temperature: saturation point, specific volume, enthalpy and entropy, worked out with IAPWS-IF97.
Silicone, FKM, PTFE, IIR, TPV, TPE and ULDPE against 50 chemicals, rated A to D from the Venair catalogue: the check before choosing a hose.
Bore, length and flow in; pressure drop, velocity and flow regime out, with every step of the sum shown.
Frequently asked questions
A hose designed for hygienic processes: a smooth bore that does not shed particles, materials suitable for contact with the product and a construction that withstands cleaning in place and sterilisation.
That the material passed the United States Pharmacopeia’s biological reactivity tests for Class VI plastics, the most demanding of its six classes. It is the usual minimum for elastomers in contact with pharmaceutical products.
One with a fluoropolymer bore. Venaflon® HF and HF-X put a USP Class VI PFA layer inside a silicone hose and Venaflon® HR inside EPDM; Venaflon® Full-X is fully conductive, for areas that need the highest safety. See all chemical resistant hoses.
Elastic, fully smooth silicone compensators and sleeves, FDA and USP Class VI: Vena® Pharmaloader, Pharmaloader Plus for high pressure and Vena® Sleeve. See all flexible connectors.
Tell us about your need and we will create the optimal solution for your company.